KS1000 SF Secret Fix

Thermal Insulation

Panel Thickness (mm) U value W/m²K
40 0.46
50 0.38
60 0.30
80 0.25
100 0.20
120 0.16

U value -Thermal transmittance W/m²K
U-values calculated in accordance with the method required by Part L2 (England & Wales) Building Regulations and Section 6 (Scotland) Technical Handbooks.

Biological

Kingspan panels are resistant to attack from mould, fungi, mildew and vermin. No urea formaldehyde is used in the construction, and the panels are not considered deleterious.

Fire

The external and internal faces of the panel to be Class 0 in accordance with the Building
Regulations when tested to BS476: Parts 6: 1989 and Part 7: 1987.
The panel must be rated SAA when tested to BS476: Part 3: 1975.
The system has passed all the requirements of LPS1181: 2003: Part 1: Issue 1, ceiling lining tests..

Acoustics

Kingspan KS1000 SF panels have a single figure weighted sound reduction Rw = 25dB.

Sound Reduction Index (SRI) Tested  
Frequency Hz 63 125 250 500 1k 2k 4k 8k
SRI dB 20 18 20 24 20 29 39 47

Air Leakage
Overall air leakage for complete envelope less than 10m3/m2/hr at 50Pa.

 